Thermowell Wake-Frequency Check
Shedding ratio with 0.8 PASS limit.
Result
Shedding/natural ratio
0.182
PASS (1=yes)
1
Calculation details
Natural freq (Hz)
550.0
Shedding freq (Hz)
100.0
Formula
Calculation logicVerify
Check before relying.
Ratio under 0.8 or redesign.
- Insertion, bore and velocity measured
- Process density at flowing conditions
- Shorten or fatten when flagged
Related calculators
Rtd temperature
NTC Beta Temperature
Beta-model resistance to temp.
- Temperature (C)
- Temperature (F)
Rtd temperature
PT100/PT1000 Resistance to Temperature
CVD quadratic solution t>=0.
- Temperature (C)
- Temperature (F)
Rtd temperature
Pyrometer Emissivity Correction
Stefan-Boltzmann correction with delta.
- True temperature (C)
- Correction (C)
Rtd temperature
RTD Alpha 3850/3926 Conversion
Resistance between alpha standards via CVD.
- Converted resistance (ohm)
- Estimated T (C)
Workspace
Keep the assumptions with the result.
Save this calculation to return to the inputs, result, and report from your private workspace.