Skip to content
SenseCalc

Thermocouple mV to Temperature

Type K with cold-junction compensation.

Inputs

Measurement

Thermocouple voltage at the instrument terminals.

Terminal temperature. Built-in CJC or measured locally.

41 for Type K, 51 for J near room temp, 41 for T, 39 for N.

Result

Hot junction (C)
124.9
Calculation details
Hot-junction equivalent (mV)
5.121
Hot junction (F)
256.8

Verify

Check before relying.

Compute before wiring, scaling, or signing the sheet.

  • Nameplate range
  • Module configuration
  • Calibrator reading
This calculator is a first-pass screening tool. Verify nameplate data, wiring, module configuration, and calibrator readings before acting.

Related calculators

Workspace

Keep the assumptions with the result.

Save this calculation to return to the inputs, result, and report from your private workspace.

Sign in or create an account to save this calculation.